FAM 25-95, Economy and 3000 series – FluidAqua Mobile

The FluidAqua Mobile FAM series operate on the principle of vacuum dewatering for the separation of free and dissolved water as well as free and dissolved gases from hydraulic and lubricating fluids. Thanks to the HYDAC offline filter element technology used, with its high dirt holding capacity and separation performance, the units achieve an outstanding level of efficiency. All units have an AquaSensor AS 1000 for continuous monitoring of the water content and control of the unit. It is possible to integrate a CS 1000 particle sensor for simultaneous monitoring of solid contamination in FAM 25/45/60/75/95 and FAM 3025/3045/3075/3095.

 

  • Optional: integrated heater to increase the dewatering capacity
  • Volume flows (at 50 Hz): up to approx. 95 l/min
  • Operating pressure: 0 to 4.5 bar
  • Integrated Programmable Logic Controller (PLC)
SKU
GP_1000428020
learn more ...
  • Search Bar : $SL-1000065135 [1000507172] [sg]
Shop By
Filter selection
Reset filter

FAM 25-95, Economy and 3000 series – FluidAqua Mobile


Grouped product items
FAM-25-M-2-H-10-R-H-C1-A-4
Material-No. 3583439
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
FAM-45-M-2-H-10-R-H-C1-A-4
Material-No. 3642843
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
FAM-95-M-2-A-40-WA-H-C1-AC1-4/-V
Material-No. 3646016
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
Viton
Measurement technology:
AC1=AS+CS (ISO4406:1999)
Heater:
H=Heater
each 1 PCE
FAM-45-M-2-H-10-R-H-C1-A-4/-V
Material-No. 3649383
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
Viton
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
FAM-60-M-2-H-26-R-H-C1-AC1-4
Material-No. 3649805
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
AC1=AS+CS (ISO4406:1999)
Heater:
H=Heater
each 1 PCE
FAM-75-M-2-B-26-R-H-C1-A-4
Material-No. 3727750
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
FAM-95-M-2-B-40-WA-H-C1-AC1-4
Material-No. 3768641
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
AC1=AS+CS (ISO4406:1999)
Heater:
H=Heater
each 1 PCE
FAM-75E-M-2-A-100-R-H-C1-A-00
Material-No. 3772161
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
FAM-45E-M-2-A-50-R-H-C1-A-00
Material-No. 3772164
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
FAM-75-M-1-H-26-R-H-C1-AC1-4
Material-No. 3776482
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
AC1=AS+CS (ISO4406:1999)
Heater:
H=Heater
each 1 PCE
FAM-25-X-2-A-10-R-Z-C1-A-4
Material-No. 3796508
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
Z=w/o heater
each 1 PCE
FAM-25-M-2-B-10-R-H-C1-A-4
Material-No. 3832062
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
FAM-75-M-2-A-26-R-H-C1-A-4/-V
Material-No. 3835943
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
Viton
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
FAM-95-M-2-H-26-R-H-C1-AC1-4
Material-No. 3840856
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
AC1=AS+CS (ISO4406:1999)
Heater:
H=Heater
each 1 PCE
FAM-75-M-2-H-26-R-H-C1-A-4
Material-No. 3862258
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
FAM-75-M-2-O-26-R-H-C1-A-4
Material-No. 3862505
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
FAM-45-M-2-O-10-R-H-C1-A-4
Material-No. 3862511
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
FAM-45E-M-2-B-50-R-H-C1-A-00
Material-No. 3921206
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
FAM-75E-M-2-B-100-R-H-C1-A-00
Material-No. 3921207
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
FAM-45E-M-2-H-50-R-H-C1-A-00
Material-No. 3921208
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
Page

Downloads

CAD data can't be found at the product category level, but directly on the individual products.
Media
FAM25/45/60/75/95 FluidAqua Mobil
Product brochure EN

(1.86 MB)

FAM 3000 series FluidAqua Mobil
Product brochure EN

(2.07 MB)

FAM Economy Series - FluidAqua Mobil
Product brochure EN

(1.69 MB)