HDA 4300 – Relative pressure, accuracy 0.5%, industry, mobile
- Ceramic measuring sensor with thick-layer strain gauge
- Measuring range 1.0…40 bar
- Accuracy ± 0.5% FS type; ± 1.0% FS max
- Analogue/IO-Link/CAN
- Options:
- Explosion-proof applications
- Ship
SKU
learn more ...
GP_1000213551
Product Search
Filter selection
Reset filter
HDA 4300 – Relative pressure, accuracy 0.5%, industry, mobile
|
HDA 4344-A-0010-000-E1
Material-No. 927170
|
|
||||||||
|
HDA 4344-A-06,0-000-E1
Material-No. 927171
|
|
||||||||
|
HDA 4344-A-0016-000-E1
Material-No. 927172
|
|
||||||||
|
HDA 4386-A-0015-CNB-000-F1(-15..+15psi)
Material-No. 927400
|
|
||||||||
|
HDA 4386-A-0015-CNB-000-F1(psi)
Material-No. 927412
|
|
||||||||
|
HDA 4345-A-06,0-EN1-000-F1
Material-No. 927419
|
|
||||||||
|
HDA 4346-A-0005-S00-F1(-1...5bar)
Material-No. 927420
|
|
||||||||
|
HDA 4385-A-0015-CNB-000-F1(psi)
Material-No. 927483
|
|
||||||||
|
HDA 4345-A-0001-000-F1(-1..+1bar) + PP
Material-No. 927522
|
|
||||||||
|
HDA 4346-A-0006-ENA-000-F1
Material-No. 927570
|
|
||||||||
|
HDA 4345-A-0040-EN1-000-F1
Material-No. 927587
|
|
||||||||
|
HDA 4386-A-0015-EN1-000-E1(psi)
Material-No. 927831
|
|
||||||||
|
HDA 4386-A-0250-EN1-000-E1(psi)
Material-No. 927832
|
|
||||||||
|
HDA 4386-A-0014-000-F1(-14,5..+14,5psi)
Material-No. 927864
|
|
||||||||
|
HDA 4345-A-02,5-EN1-000-F1
Material-No. 927907
|
|
||||||||
|
HDA 4346-A-0001-EN1-000-F1(-1..+1bar)
Material-No. 928289
|
|
||||||||
|
HDA 4346-A-01,0-S00-E1
Material-No. 928406
|
|
||||||||
|
HDA 4315-B-02,5-000-E1
Material-No. 928510
|
|
||||||||
|
HDA 4346-A-0040-EN1-000-E1
Material-No. 928516
|
|
||||||||
|
HDA 4346-A-0040-EN1-000-E1 + PP
Material-No. 928517
|
|
Downloads
CAD data can’t be found at the product category level. Instead, it can be found directly at an individual product level.
Media
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_BUW/PRD_DOC_BUW_669687-00001.jpg)
HDA 4100/4300 User manual D/E/F
Operating/maintenance instructions
EN
(0.39 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_BUW/PRD_DOC_BUW_669704-00001.jpg)
HDA 4100/4300/4400/4700 ship User manual D/E
Operating/maintenance instructions
EN
(0.25 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_BUW/PRD_DOC_BUW_669717-00001.jpg)
HDA 4100/4300/4400/4700 Ex ia CSA User manual E
Operating/maintenance instructions
EN
(1.48 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_BUW/PRD_DOC_BUW_669723-00001.jpg)
HDA 4100/4300/4400/4700 Ex ia ATEX User manual D/E
Operating/maintenance instructions
EN
(3.47 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_BUW/PRD_DOC_BUW_669746-00001.jpg)
HDA 4100/4300/4400/47000 IECEx User manual D/E
Operating/maintenance instructions
EN
(5.25 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_BUW/PRD_DOC_BUW_669911-00001.jpg)
HDA 4100/4300/4400/4700 Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions
EN
(4.37 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_PRO/PRD_DOC_PRO_18074-00001.jpg)
HDA 4300 Pressure Transmitter Ex applications ATEX, IECEx
Product brochure
EN
(0.77 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_PRO/PRD_DOC_PRO_18105-00001.jpg)
HDA 4300 Pressure Transmitter Ex applications IECEx Australia approval
Product brochure
EN
(0.77 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_PRO/PRD_DOC_PRO_18323-00001.jpg)
HDA 4300 Pressure Transmitter
Product brochure
EN
(0.89 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_PRO/PRD_DOC_PRO_18324-00001.jpg)
HDA 4300 Pressure Transmitter shipping applications
Product brochure
EN
(5.13 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_PRO/PRD_DOC_PRO_18337-00001.jpg)
Electronic Pressure Transmitter in ATEX Version HDA 4300
Product brochure
EN
(0.86 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_PRO/PRD_DOC_PRO_18343-00001.jpg)
HDA 4300 Pressure Transmitter Ex applications
Product brochure
EN
(0.79 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_PRO/PRD_DOC_PRO_18376-00001.jpg)
Electronic Pressure Transmitter HDA 4300 with Flush Membrane
Product brochure
EN
(0.83 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_PRO/PRD_DOC_PRO_183762-00001.jpg)
Electronic Pressure Transmitter HDA 4300 with Flush Membrane IECExIntrinsically Safe IECEx Dustproof Enclosure IECEx Non-sparking
Product brochure
EN
(0.87 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_PRO/PRD_DOC_PRO_183763-00001.jpg)
Electronic Pressure Transmitter HDA 4300 with Flush Membrane ATEXIntrinsically Safe ATEX Dustproof Enclosure ATEX Non-sparking
Product brochure
EN
(0.86 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_PRO/PRD_DOC_PRO_183923-00001.jpg)
Electronic Pressure Transmitter HDA 4300 IECEx Intrinsically Safe IECExDustproof Enclosure IECEx Non-sparking
Product brochure
EN
(0.88 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_PRO/PRD_DOC_PRO_18630-00001.jpg)
HDA 4300 Pressure Transmitter Ex applications ATEX, IECEx, HART
Product brochure
EN
(0.78 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_BUW/PRD_DOC_BUW_669995-00001.jpg)
HDA 4100/4300/4400/4700 HART Ex ia CSA User manual E
Operating/maintenance instructions
EN
(1.72 MB)
![](https://www.hydac.com/shop/media//catalog/crossbase/thumbnail/PRD_DOC_BUW/PRD_DOC_BUW_669905-00001.jpg)
HDA 4100/4300/4400/4700 HART Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions
EN
(2.51 MB)