HLT 1100 – Analogue, digital, fully cylinder-integrated

  • Magnetostrictive
  • Measuring range 50 ... 4000 mm
  • Resolution 0.1 mm
  • Analog / CANopen / CANopen Safety / SSI
  •  Options:
    • Increased functional safety
    • Various electrical connectors

 

 

 

SKU
GP_1000266906
learn more ...
  • Search Bar : $SL-1000065920 [1000512887] [my]
Product Search
Filter selection
Reset filter
Measuring range [mm]
Select all Reset selection
Output signal
Select all Reset selection
Electrical connection
Select all Reset selection
Approvals and certificates
Select all Reset selection

HLT 1100 – Analogue, digital, fully cylinder-integrated


Grouped product items
HLT 1100-R2-K10-C01-0735-000
Material-No. 921734
Electrical connection:
Jacketed cable, length 10 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
4 .. 20 mA (3-conductor)
Resolution:
0.1 mm
PCE
HLT 1100-R2-K02-C01-0550-000
Material-No. 921789
Electrical connection:
Jacketed cable, length 2 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
4 .. 20 mA (3-conductor)
Resolution:
0.1 mm
PCE
HLT 1100-R2-K01-F11-0400-000
Material-No. 921819
Electrical connection:
Jacketed cable, length 1 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
CANopen
Resolution:
0.1 mm
PCE
HLT 1100-R2-K10-F11-1350-000
Material-No. 921820
Electrical connection:
Jacketed cable, length 10 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
CANopen
Resolution:
0.1 mm
PCE
HLT 1100-R2-K01-F11-0410-000
Material-No. 922044
Electrical connection:
Jacketed cable, length 1 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
CANopen
Resolution:
0.1 mm
PCE
HLT 1100-R2-K05-C01-0700-000
Material-No. 922238
Electrical connection:
Jacketed cable, length 5 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
4 .. 20 mA (3-conductor)
Resolution:
0.1 mm
PCE
HLT 1100-R2-K01-C01-0300-000
Material-No. 922319
Electrical connection:
Jacketed cable, length 1 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
4 .. 20 mA (3-conductor)
Resolution:
0.1 mm
PCE
HLT 1100-R2-K05-F13-1000-S2PD-000
Material-No. 922432
Electrical connection:
Jacketed cable, length 5 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
CANopen Safety
Resolution:
0.1 mm
PCE
HLT 1100-R2-L06-G04-0130-000
Material-No. 922436
Electrical connection:
M12x1, single conductor 60 mm
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
0.5 to 4.5 V
Resolution:
0.1 mm
PCE
HLT 1100-R2-L10-C01-0750-000
Material-No. 922923
Electrical connection:
M12x1, single conductor 100 mm
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
4 .. 20 mA (3-conductor)
Resolution:
0.1 mm
PCE
HLT 1100-R2-K10-C01-0780-000
Material-No. 922983
Electrical connection:
Jacketed cable, length 10 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
4 .. 20 mA (3-conductor)
Resolution:
0.1 mm
PCE
HLT 1100-R2-K01-G01-1170-000
Material-No. 923007
Electrical connection:
Jacketed cable, length 1 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
0.25 to 4.75 V
Resolution:
0.1 mm
PCE
HLT 1100-R2-K01-G01-0160-000
Material-No. 923128
Electrical connection:
Jacketed cable, length 1 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
0.25 to 4.75 V
Resolution:
0.1 mm
PCE
HLT 1100-R2-K01-C01-0700-000
Material-No. 923140
Electrical connection:
Jacketed cable, length 1 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
4 .. 20 mA (3-conductor)
Resolution:
0.1 mm
PCE
HLT 1100-R2-K10-C01-0715-000
Material-No. 923157
Electrical connection:
Jacketed cable, length 10 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
4 .. 20 mA (3-conductor)
Resolution:
0.1 mm
PCE
HLT 1100-R2-K10-C01-0910-000
Material-No. 923158
Electrical connection:
Jacketed cable, length 10 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
4 .. 20 mA (3-conductor)
Resolution:
0.1 mm
PCE
HLT 1100-R2-K01-C01-0270-000
Material-No. 923176
Electrical connection:
Jacketed cable, length 1 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
4 .. 20 mA (3-conductor)
Resolution:
0.1 mm
PCE
HLT 1100-R2-K01-G01-1640-000
Material-No. 923177
Electrical connection:
Jacketed cable, length 1 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
0.25 to 4.75 V
Resolution:
0.1 mm
PCE
HLT 1100-R2-K10-C01-0080-000
Material-No. 923213
Electrical connection:
Jacketed cable, length 10 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
4 .. 20 mA (3-conductor)
Resolution:
0.1 mm
PCE
HLT 1100-R2-K02-G01-0080-000
Material-No. 923258
Electrical connection:
Jacketed cable, length 2 m
Mechanical connection:
Cylinder-integrated, D=10 mm
Output signal:
0.25 to 4.75 V
Resolution:
0.1 mm
PCE
Page

Downloads

CAD data can’t be found at the product category level. Instead, it can be found directly at an individual product level.
Media
HLT 1100 Analog Safety Safety manual D/E
Operating/maintenance instructions EN

(1.75 MB)

HLT 1100 CANopen Safety Safety manual D/E
Operating/maintenance instructions EN

(1.68 MB)

HLT 1100-R2 Analogue User manual D/E
Operating/maintenance instructions EN

(0.7 MB)

HLT 1100-R2 CANopen+SAE J1939 User manual D/E/F
Operating/maintenance instructions EN

(2.4 MB)

HLT 1100-R2 Analogue Safety User manual D/E/F
Operating/maintenance instructions EN

(1.13 MB)

HLT 1100-R2 CANopen Safety User manual D/E/F
Operating/maintenance instructions EN

(1.09 MB)

HLT 1100 CANopen Safety Protocol description E
Operating/maintenance instructions EN

(0.65 MB)

HLT 1100-R2 Linear Position Transmitter
Product brochure EN

(0.76 MB)

HLT 1100-R2 Linear Position Transmitter PL d, SIL 2
Product brochure EN

(0.75 MB)

HLT 1100-R2 Linear Position Transmitter CANopen Safety PL d, SIL 2
Product brochure EN

(0.81 MB)

HLT 1100-R2 Linear Position Transmitter CANopen
Product brochure EN

(0.82 MB)

HLT 1100 CANopen Safety(HLT1k-3 V03) Protocol description E
Operating/maintenance instructions EN

(0.6 MB)

HLT 1100/2150/2550 CANopen Protocol description E
Operating/maintenance instructions EN

(4.96 MB)

HLT 1100 SAE J1939 Protocol description E
Operating/maintenance instructions EN

(0.89 MB)