ETS 4100

Available versions:

  • Standard
  • With HSI sensor detection
  • HART interface
  • CANopen / SAE J1939
  • IO-Link interface
  • also available as a "smart" version

The ETS 4100 is an electronic temperature transmitter which, because of its robust design, is used in particular for temperature measurement in hydraulic applications in industry.   With the temperature sensor, based on a PT 1000 and corresponding evaluation electronics, temperatures ranging from -25°C to +100°C can be measured. The analogue output signals from 4 .. 20 mA and 0 .. 10V are available on the standard version for integration into modern controls. With a pressure resistance of up to 600 bar and excellent EMC properties, the ETS 4100 is ideally suited for utilisation, even in rough environments.   The electronic temperature transmitter ETS 4148-H with HSI sensor detection was specially developed for use in conjunction with the HYDAC measuring instruments HMG 500, HMG 510, HMG 4000 and CMU 1000. For data transmission, the ETS 4148-H has an HSI interface (HYDAC Sensor Interface). The HSI sensors are automatically recognised via the HSI interface by the above-mentioned HYDAC measuring instruments and all necessary basic device settings are taken from each sensor.    

  • Accuracy 0.8% FS
  • Ideal for industrial applications
  • Robust construction
  • Excellent EMC characteristics
  • Good long-term stability
  • Standard protection class IP 65
SKU
GP_1000189349
learn more ...
  • Search Bar : $SL-1000063977 [1000505517] [my]
Product Search
Filter selection
Reset filter
Output signal
Select all Reset selection
Mechanical connection
Select all Reset selection
Sensor length [mm]
Select all Reset selection
Electrical connection
Select all Reset selection
Show more filters

ETS 4100


Grouped product items
ETS 4144-A-006-000
Material-No. 903381
Probe length:
6
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
Binder series 714 M18 / 4p
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4146-B-006-000
Material-No. 908335
Probe length:
6
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4146-A-006-000
Material-No. 909119
Probe length:
6
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4146-A-100-000
Material-No. 923605
Probe length:
100
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4146-A-050-000
Material-No. 923732
Probe length:
50
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4144-B-100-000
Material-No. 923863
Probe length:
100
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
Binder series 714 M18 / 4p
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4146-B-050-000
Material-No. 924225
Probe length:
50
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4144-A-100-000
Material-No. 924505
Probe length:
100
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
Binder series 714 M18 / 4p
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4146-A-250-000
Material-No. 924608
Probe length:
250
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4146-A-350-000
Material-No. 924609
Probe length:
350
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4146-B-100-000
Material-No. 924857
Probe length:
100
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4148-F11-100-000
Material-No. 924909
Probe length:
100
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
M12x1 / 5p
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4146-F21-250-000
Material-No. 924930
Probe length:
250
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4144-B-250-000
Material-No. 925128
Probe length:
250
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
Binder series 714 M18 / 4p
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4146-F21-100-000
Material-No. 925136
Probe length:
100
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4144-A-050-000
Material-No. 925153
Probe length:
50
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
Binder series 714 M18 / 4p
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4145-B-006-000
Material-No. 925266
Probe length:
6
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
DIN 43650 /3p+PE
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4145-A-006-000
Material-No. 925289
Probe length:
6
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
DIN 43650 /3p+PE
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 4145-A-050-000
Material-No. 925573
Probe length:
50
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
DIN 43650 /3p+PE
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
ETS 414G-F21-100-D-000 (2m)
Material-No. 925756
Probe length:
100
Accuracy:
0.8% max = 0.4% typ.
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Mechanical connection:
G1/4 A DIN 3852 / external
PCE
Page

Downloads

CAD data can’t be found at the product category level. Instead, it can be found directly at an individual product level.
Media
ETS 4100/4500 User manual D/E/F
Operating/maintenance instructions EN

(0.89 MB)

ETS 4100/4500 HART ExD ATEX IECEx CSA User manual D/E
Operating/maintenance instructions EN

(2.8 MB)

ETS 4100/4500 HART Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions EN

(2.87 MB)

ETS 4100 HART User manual D/E
Operating/maintenance instructions EN

(0.57 MB)

ETS 4100 IO-Link User manual D/E
Operating/maintenance instructions EN

(1.11 MB)

ETS 4100S IO-Link User manual D/E
Operating/maintenance instructions EN

(1.27 MB)

ETS 4100/4500 SAEJ1939 Protocol description E
Operating/maintenance instructions EN

(0.48 MB)

ETS 4100/4500 SAE J1939 V03 Protocol description E
Operating/maintenance instructions EN

(0.5 MB)

ETS 4100 Temperature Transmitter
Product brochure EN

(0.82 MB)

ETS 4100 Temperature Transmitter Ex applications ATEX, IECEx, HART
Product brochure EN

(0.85 MB)

ETS 4100 Temperature Transmitter, HART
Product brochure EN

(0.86 MB)

ETS 4100 CAN Temperature Transmitter
Product brochure EN

(4.66 MB)

ETS 4100/4100S CANopen Protocol description E
Operating/maintenance instructions EN

(4.88 MB)

ETS 4100/4100S IO-Link Compact instructions D/E
Operating/maintenance instructions EN

(0.88 MB)

ETS 4100 CANopen+SAE J1939 User manual D/E
Operating/maintenance instructions EN

(1.02 MB)

ETS 4100 IO-Link Temperature Transmitter
Product brochure EN

(0.5 MB)

ETS 4100 Temperature Transmitter Ex applications ATEX, IECEx, CSA, HART
Product brochure EN

(0.83 MB)

ETS 4100 Temperature Transmitter Ex applicationsATEX, IECEx, CSA, triple approval, HART interface
Product brochure EN

(0.87 MB)

ETS 4100Smart IO-Link Temperature Transmitter
Product brochure EN

(0.49 MB)