FAM 25-95, Economy and 3000 series – FluidAqua Mobile

The FluidAqua Mobile FAM series operate on the principle of vacuum dewatering for the separation of free and dissolved water as well as free and dissolved gases from hydraulic and lubricating fluids. Thanks to the HYDAC offline filter element technology used, with its high dirt holding capacity and separation performance, the units achieve an outstanding level of efficiency. All units have an AquaSensor AS 1000 for continuous monitoring of the water content and control of the unit. It is possible to integrate a CS 1000 particle sensor for simultaneous monitoring of solid contamination in FAM 25/45/60/75/95 and FAM 3025/3045/3075/3095.

 

  • Optional: integrated heater to increase the dewatering capacity
  • Volume flows (at 50 Hz): up to approx. 95 l/min
  • Operating pressure: 0 to 4.5 bar
  • Integrated Programmable Logic Controller (PLC)
SKU
GP_1000428020
learn more ...
  • Search Bar : $SL-1000065135 [1000507172] [in]
Product Search
Filter selection
Reset filter

FAM 25-95, Economy and 3000 series – FluidAqua Mobile


Grouped product items
FAM-45-M-2-A-10-R-H-C1-AC1-4/-V
Material-No. 3412824
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
Viton
Measurement technology:
AC1=AS+CS (ISO4406:1999)
Heater:
H=Heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-25-M-2-A-10-R-H-C1-AC1-4/-V
Material-No. 3427231
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
Viton
Measurement technology:
AC1=AS+CS (ISO4406:1999)
Heater:
H=Heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-25-M-2-A-10-R-H-C1-AC1-4
Material-No. 3428488
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
AC1=AS+CS (ISO4406:1999)
Heater:
H=Heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-60-M-2-A-26-R-H-C1-A-4/-V
Material-No. 3441060
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
Viton
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-75-M-2-A-26-R-H-C1-A-4
Material-No. 3441519
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-75-M-2-A-40-R-Z-C1-A-4
Material-No. 3455924
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
Z=w/o heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-25-M-2-A-10-R-Z-C1-A-4
Material-No. 3472564
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
Z=w/o heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-45-M-2-A-10-R-H-C1-AC1-4
Material-No. 3476408
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
AC1=AS+CS (ISO4406:1999)
Heater:
H=Heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-45-M-2-B-10-R-H-C1-A-4
Material-No. 3478895
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-25-M-2-A-10-R-H-C1-A-4
Material-No. 3479609
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-60-M-2-A-26-R-H-C1-A-4
Material-No. 3484647
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-45-M-2-A-10-R-H-C1-A-4
Material-No. 3492716
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-75-M-2-A-26-R-Z-C1-A-4
Material-No. 3492717
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
Z=w/o heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-95-M-2-A-26-R-Z-C1-A-4
Material-No. 3492718
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
Z=w/o heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-95-M-2-A-26-R-H-C1-A-4
Material-No. 3492719
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-25-I-2-A-10-R-H-C1-A-4
Material-No. 3516633
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-45-M-2-A-10-R-H-C1-A-4/-V
Material-No. 3532501
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
Viton
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-25-M-2-O-10-R-H-C1-A-4
Material-No. 3547092
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-60-M-2-A-40-R-H-C1-A-4
Material-No. 3571303
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
FAM-25-M-1-B-10-R-H-C1-A-4
Material-No. 3583161
Standard:
EN ISO 12100:2010, EN 60204-1:2018, EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011, EN 55011:2009 + A1:2010, EN ISO 13732-1:2008, EN ISO 4413:2010, EN 894-1:1997 + A1:2008
Supplementary details:
None
Measurement technology:
A=AquaSensor
Heater:
H=Heater
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
Page

Downloads

CAD data can’t be found at the product category level. Instead, it can be found directly at an individual product level.
Media
FAM25/45/60/75/95 FluidAqua Mobil
Product brochure EN

(1.86 MB)

FAM 3000 series FluidAqua Mobil
Product brochure EN

(2.07 MB)

FAM Economy Series - FluidAqua Mobil
Product brochure EN

(1.69 MB)