EDS 4400 – Fixed, high pressure, relative, industry, mobile

  • Stainless steel measuring sensor, thin-film strain gauge
  • High pressure 40 bar...1000 bar, relative
  • Solid version, A/F width 27
  • 1 or 2 adjustable transistor outputs
    • PNP or NPN
    • Switching accuracy± 0.5% FS type
    • Switching current 1 x 1.2 A or 2 x 1 A
  • Options
    • Explosion-proof applications
    • Hydrogen applications
    • Z = Flush membrane
SKU
GP_1000213602
learn more ...
  • Search Bar : $SL-1000063860 [1000505489] [in]
Product Search
Filter selection
Reset filter
Pressure unit
Select all Reset selection
Setting range max value
Select all Reset selection
Switching outputs
Select all Reset selection
Additional interface
Select all Reset selection
Show more filters

EDS 4400 – Fixed, high pressure, relative, industry, mobile


Grouped product items
EDS 444G-0250-2P-DS-000(10m)
Material-No. 929161
Approvals and certificates:
ATEX
Additional interface:
No
Electrical connection:
Cable
Mechanical connection:
G1/4 A ISO 1179-2 / external
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
EDS 444G-0060-1P-DS-000(10m)
Material-No. 929240
Approvals and certificates:
ATEX
Additional interface:
No
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Mechanical connection:
G1/4 A ISO 1179-2 / external
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
EDS 44F9-0100-1P-DV-000(PSI)72inch
Material-No. 929784
Approvals and certificates:
ATEX
Additional interface:
No
Electrical connection:
Conduit 1/2-14 NPT single lead
Mechanical connection:
1/4-18 NPT / internal
each 1 PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
Page

Downloads

CAD data can’t be found at the product category level. Instead, it can be found directly at an individual product level.
Media
EDS 4100/4300/4400 ATEX User manual D/E
Operating/maintenance instructions EN

(2.43 MB)

EDS 4400 programmable User manual D/E/F
Operating/maintenance instructions EN

(0.51 MB)

EDS 4400 ExD ATEX IECEx CSA User manual D/E
Operating/maintenance instructions EN

(7.72 MB)

EDS 4400 Pressure Switch
Product brochure EN

(0.82 MB)

EDS 4400 Pressure Switch Ex applications ATEX approval
Product brochure EN

(0.85 MB)

EDS 4400 Pressure Switch Ex series applications ATEX, CSA, IECEx
Product brochure EN

(0.86 MB)

EDS 4400 Pressure Switch Ex applications ATEX, CSA, IECEx
Product brochure EN

(0.91 MB)

EDS 4400 Pressure Switch Ex series applications ATEX approval
Product brochure EN

(0.78 MB)