HDA 4700 – Relative pressure, accuracy 0.25%, industry, mobile
- Stainless steel measuring sensor with thin-film strain gauge
- Measuring range 2.5…2000 bar
- Accuracy ± 0.25% FS type; ± 0.5% FS max
- Analog/IO-Link/CAN/HART
- Options:
- Flush membrane
- Increased functional safety
- Explosion-proof applications
- Hydrogen
- Ship
Material number
learn more ...
GP_1000213555
- Search Bar : $SL-1000063746 [1000505463] [uk]
Product Search
Filter selection
Reset filter
In Stock
HDA 4700 – Relative pressure, accuracy 0.25%, industry, mobile
|
HDA 4745-A-016-031(10bar)
Material-No. 925272
Upon request
|
|
Please log in for prices | |||||||
|
HDA 4745-A-0250-ANC-000
Material-No. 925347
Upon request
|
|
Please log in for prices | |||||||
|
HDA 4726-A-1000-EN1-000
Material-No. 925539
Product not in stock
Delivery time on request
|
|
Please log in for prices | |||||||
|
HDA 4746-A-0600-EN1-000
Material-No. 925540
Product not in stock
Delivery time on request
|
|
Please log in for prices | |||||||
|
HDA 4746-CC-0400-0600-Pd-000
Material-No. 925551
Upon request
|
|
Please log in for prices | |||||||
|
HDA 4744-A-250-031(100bar)
Material-No. 925558
Upon request
|
|
Please log in for prices | |||||||
|
HDA 47Z5-A-0250-G02-000
Material-No. 925581
Upon request
|
|
Please log in for prices | |||||||
|
HDA 47ZG-A-0400-G01-DS-000(10m)
Material-No. 925594
Upon request
|
|
Please log in for prices | |||||||
|
HDA 47CG-A-1000-DS-000(2m)
Material-No. 925622
Upon request
|
|
Please log in for prices | |||||||
|
HDA 474G-A-0020-DV-000(2m)
Material-No. 925623
Upon request
|
|
Please log in for prices | |||||||
|
HDA 47Z5-B-0250-G01-000
Material-No. 925736
Upon request
|
|
Please log in for prices | |||||||
|
HDA 47Z5-A-0250-G01-ANC-000
Material-No. 925738
Upon request
|
|
Please log in for prices | |||||||
|
HDA 47Z5-A-0400-G01-ANC-000
Material-No. 925739
Upon request
|
|
Please log in for prices | |||||||
|
HDA 47Z5-A-0040-G01-ANC-000
Material-No. 925748
Upon request
|
|
Please log in for prices | |||||||
|
HDA 4746-CC-0040-0040-Pd-031(-1..+40bar)
Material-No. 925749
Upon request
|
|
Please log in for prices | |||||||
|
HDA 47B9-A-20000-DS-000(PSI)72inch
Material-No. 925757
Upon request
|
|
Please log in for prices | |||||||
|
HDA 474G-F21-0006-DV-000 (2m)
Material-No. 925758
Upon request
|
|
Please log in for prices | |||||||
|
HDA 474G-F21-0250-DS-000 (2m)
Material-No. 925759
Upon request
|
|
Please log in for prices | |||||||
|
HDA 478G-A-0200-DV-000(psi)10m
Material-No. 925774
Upon request
|
|
Please log in for prices | |||||||
|
HDA 47C9-A-1000-DS-000(2m)
Material-No. 925775
Upon request
|
|
Please log in for prices |
Downloads
CAD data can’t be found at the product category level. Instead, it can be found directly at an individual product level.
Media
HDA 4400/4700 User manual D/E/F
Operating/maintenance instructions
EN
(1.91 MB)
HDA 4700 CANopen+SAE J1939 User manual D/E
Operating/maintenance instructions
EN
(0.36 MB)
HDA 4100/4300/4400/4700 ship User manual D/E
Operating/maintenance instructions
EN
(0.25 MB)
HDA 4100/4300/4400/4700 Ex ia CSA User manual E
Operating/maintenance instructions
EN
(1.48 MB)
HDA 4100/4300/4400/4700 Ex ia ATEX User manual D/E
Operating/maintenance instructions
EN
(3.47 MB)
HDA 4400/4700/EDS 410 Ex-Proof User manual E
Operating/maintenance instructions
EN
(0.85 MB)
HDA 4100/4300/4400/47000 IECEx User manual D/E
Operating/maintenance instructions
EN
(5.25 MB)
HDA 4700/7400/7700 CANopen Protocol description D/E
Operating/maintenance instructions
EN
(0.61 MB)
HDA 4400/4700 ExD ATEX IECEx CSA User manual D/E
Operating/maintenance instructions
EN
(10.78 MB)
HDA 4400/4700-CC Analogue Safety Safety manual D/E
Operating/maintenance instructions
EN
(0.74 MB)
HDA 4400/4700 flash membrane User manual D/E/F
Operating/maintenance instructions
EN
(0.61 MB)
HDA 4700/7400/7700 SAE J1939 Protocol description D/E
Operating/maintenance instructions
EN
(0.24 MB)
HDA 4100/4300/4400/4700 HART Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions
EN
(2.51 MB)
HDA 4100/4300/4400/4700 Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions
EN
(4.37 MB)
HDA 4400/4700 ExD HART ATEX IECEs CSA User manual D/E
Operating/maintenance instructions
EN
(3.35 MB)
HDA 4700 HART User manual D/E
Operating/maintenance instructions
EN
(0.58 MB)
HDA 4400/4700-AA Ex ia ATEX IECEx for H2 User manual D/E
Operating/maintenance instructions
EN
(7.62 MB)
HDA 4400/4700 Ex ia ATEX IECEx for H2 User manual D/E
Operating/maintenance instructions
EN
(6.54 MB)
HDA 4400/4700-AA Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions
EN
(4.36 MB)
HDA 4400/4700 Ex ia CSA for H2 User manual E
Operating/maintenance instructions
EN
(3.12 MB)
HDA 4400/4700 ExD ATEX IECEx CSA für H2 User manual D/E
Operating/maintenance instructions
EN
(13.04 MB)
HDA 4400/4700 HART Ex ia ATEX IECEX for H2 User manual D/E
Operating/maintenance instructions
EN
(2.17 MB)
HDA 4400/4700-A Ex ia SIL2 PLd ATEX IECEx User manual+Safety manual D/E
Operating/maintenance instructions
EN
(5.01 MB)
HDA 4400/4700-A Ex ia SIL2 PLd ATEX IECEx for H2 User manual+Safety manual D/E
Operating/maintenance instructions
EN
(5.23 MB)
HDA 4700 SAE J1939 V03 Protocol description E
Operating/maintenance instructions
EN
(0.81 MB)
HDA 4700 Bluetooth Ex ia ATEX IECEx User manual E/D
Operating/maintenance instructions
EN
(1.9 MB)
HDA 4700 CANopen Safety SIL3 PLe Safety manual D/E
Operating/maintenance instructions
EN
(3.36 MB)
HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx
Product brochure
EN
(0.8 MB)
HDA 4700 Pressure Transmitter Ex applicationsATEX, IECEx, CSA, triple approval, HART interface
Product brochure
EN
(0.86 MB)
HDA 4700 Pressure Transmitter Ex applications IECEx Australia approval
Product brochure
EN
(0.77 MB)
HDA 4700 Pressure Transmitter SIL 3, PLe
Product brochure
EN
(3.59 MB)
HDA 4700 Pressure Transmitter
Product brochure
EN
(5.79 MB)
HDA 4700 Pressure Transmitter CAN
Product brochure
EN
(4.54 MB)
HDA 4700 Pressure Transmitter shipping applications
Product brochure
EN
(4.7 MB)
Electronic Pressure Transmitter in ATEX Version HDA 4700
Product brochure
EN
(0.88 MB)
HDA 4700 Pressure Transmitter Ex applications
Product brochure
EN
(0.8 MB)
Electronic Pressure Transmitter HDA 4700 with Flush Membrane
Product brochure
EN
(0.84 MB)
Electronic Pressure Transmitter HDA 4700 with Flush Membrane ATEXIntrinsically Safe ATEX Dustproof Enclosure ATEX Non-sparking
Product brochure
EN
(0.84 MB)
Electronic Pressure Transmitter HDA 4700 with Flush Membrane ATEX,IECEx, CSA Flameproof Enclosure
Product brochure
EN
(0.79 MB)
Electronic Pressure Transmitter HDA 4700 with Flush Membrane IECExIntrinsically Safe IECEx Dustproof Enclosure IECEx Non-sparking
Product brochure
EN
(0.86 MB)
HDA 4700 Pressure Transmitter PL d Cat 3
Product brochure
EN
(5.15 MB)
HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx, CSA
Product brochure
EN
(0.87 MB)
Electronic Pressure Transmitter HDA 4700 IECEx Intrinsically safe
Product brochure
EN
(0.93 MB)
HDA 4700 Pressure Transmitter HART
Product brochure
EN
(0.79 MB)
HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx, HART
Product brochure
EN
(0.76 MB)
HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx, CSA, HART
Product brochure
EN
(0.91 MB)
HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx, Redundant
Product brochure
EN
(0.82 MB)
HDA 4100/4300/4400/4700 HART Ex ia CSA User manual E
Operating/maintenance instructions
EN
(1.72 MB)
HDA 4400/4700 CANopen Safety SIL3 PLe Protocol description E
Operating/maintenance instructions
EN