HDA 4700 – Relative pressure, accuracy 0.25%, industry, mobile

  • Stainless steel measuring sensor with thin-film strain gauge
  • Measuring range 2.5…2000 bar
  • Accuracy ± 0.25% FS type; ± 0.5% FS max
  • Analog/IO-Link/CAN/HART
  • Options:
    • Flush membrane
    • Increased functional safety
    • Explosion-proof applications
    • Hydrogen
    • Ship
Read more Show less
Material number
GP_1000213555
Product Search
Filter selection
Reset filter
Pressure unit
select all Reset selection
Setting range min value
select all Reset selection
Setting range max value
select all Reset selection
Accuracy [%]
select all Reset selection
Show more filters
Grouped product items
HDA 4744-A-016-000
Material no. 906298
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
16
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4745-A-250-031(200bar)
Material no. 906332
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
200
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4745-A-250-000
Material no. 906392
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
250
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4745-A-400-000
Material no. 906393
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
400
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4745-A-600-031(350bar)
Material no. 906503
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
350
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4745-B-400-000
Material no. 906507
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
400
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4744-A-400-000
Material no. 906604
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
400
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4745-A-100-000
Material no. 906729
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
100
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4744-A-160-000
Material no. 906911
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
160
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4775-A-0150-000(PSI)
Material no. 907184
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
150
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4775-A-1500-000(PSI)
Material no. 907187
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
1500
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4775-A-3000-000(PSI)
Material no. 907188
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
3000
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4775-A-5000-000(PSI)
Material no. 907189
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
5000
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4775-A-6000-000(PSI)
Material no. 907190
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
6000
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4775-A-9000-000(PSI)
Material no. 907191
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
9000
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4775-B-0150-000(PSI)
Material no. 907192
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
150
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4775-B-0750-000(PSI)
Material no. 907193
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
750
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4775-B-1000-000(PSI)
Material no. 907194
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
1000
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4775-B-1500-000(PSI)
Material no. 907195
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
1500
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
HDA 4775-B-3000-000(PSI)
Material no. 907196
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
3000
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
Add to my list
In the "My list" area, you can bookmark products, request them or create templates for recurring orders.
Page

Downloads

CAD data can’t be found at the product category level. Instead, it can be found directly at an individual product level.
Media
HDA 4400/4700 Operating instruction D/E
Operating/maintenance instructions EN

(9.75 MB)

HDA 4700 CANopen+SAE J1939 User manual D/E
Operating/maintenance instructions EN

(0.36 MB)

HDA 4100/4300/4400/4700 ship Operating instructions D/E
Operating/maintenance instructions EN

(8.93 MB)

HDA 4100/4300/4400/4700 Ex ia CSA User manual E
Operating/maintenance instructions EN

(1.48 MB)

HDA 4400/4700 ExD ATEX IECEx CSA User manual D/E
Operating/maintenance instructions EN

(10.78 MB)

HDA 4400/4700-CC Analogue Safety Safety manual D/E
Operating/maintenance instructions EN

(0.74 MB)

HDA 4400/4700 flash membrane User manual D/E/F
Operating/maintenance instructions EN

(0.61 MB)

HDA 4700/7400/7700 SAE J1939 Protocol description D/E
Operating/maintenance instructions EN

(0.24 MB)

HDA 4100/4300/4400/4700 HART Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions EN

(2.51 MB)

HDA 4100/4300/4400/4700 Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions EN

(4.37 MB)

HDA 4400/4700 ExD HART ATEX IECEs CSA User manual D/E
Operating/maintenance instructions EN

(3.35 MB)

HDA 4700 HART User manual D/E
Operating/maintenance instructions EN

(0.58 MB)

HDA 4400/4700-AA Ex ia ATEX IECEx for H2 User manual D/E
Operating/maintenance instructions EN

(7.62 MB)

HDA 4400/4700 Ex ia ATEX IECEx for H2 User manual D/E
Operating/maintenance instructions EN

(6.54 MB)

HDA 4400/4700-AA Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions EN

(4.36 MB)

HDA 4400/4700 Ex ia CSA for H2 User manual E
Operating/maintenance instructions EN

(3.12 MB)

HDA 4400/4700 ExD ATEX IECEx CSA für H2 User manual D/E
Operating/maintenance instructions EN

(13.04 MB)

HDA 4400/4700-A Ex ia SIL2 PLd ATEX IECEx User manual+Safety manual D/E
Operating/maintenance instructions EN

(5.01 MB)

HDA 4400/4700-A Ex ia SIL2 PLd ATEX IECEx for H2 User manual+Safety manual D/E
Operating/maintenance instructions EN

(5.23 MB)

HDA 4700 SAE J1939 V03 Protocol description E
Operating/maintenance instructions EN

(0.81 MB)

HDA 4700 CANopen Safety SIL3 PLe Safety manual D/E
Operating/maintenance instructions EN

(3.36 MB)

HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx
Product brochure EN

(0.8 MB)

HDA 4700 Pressure Transmitter Ex applicationsATEX, IECEx, CSA, triple approval, HART interface
Product brochure EN

(0.86 MB)

HDA 4700 Pressure Transmitter SIL 3, PLe
Product brochure EN

(3.59 MB)

HDA 4700 Pressure Transmitter
Product brochure EN

(5.79 MB)

HDA 4700 Pressure Transmitter CAN
Product brochure EN

(4.54 MB)

HDA 4700 Pressure Transmitter shipping applications
Product brochure EN

(4.7 MB)

HDA 4700 Pressure Transmitter Ex applications, CSA approval
Product brochure EN

(0.8 MB)

HDA 4700 Pressure Transmitter PL d Cat 3
Product brochure EN

(5.09 MB)

HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx, CSA
Product brochure EN

(0.87 MB)

HDA 4700 Pressure Transmitter HART
Product brochure EN

(4.52 MB)

HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx, HART
Product brochure EN

(0.76 MB)

HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx, CSA, HART
Product brochure EN

(0.91 MB)

HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx, Redundant
Product brochure EN

(0.82 MB)

HDA 4100/4300/4400/4700 HART Ex ia CSA User manual E
Operating/maintenance instructions EN

(1.72 MB)

HDA 4400/4700 CANopen Safety SIL3 PLe Protocol description E
Operating/maintenance instructions EN

(5.5 MB)

HDA 4700 Pressure Transmitter Ex application for Hydrogen SIL2 Pld
Product brochure EN

(2.17 MB)

HDA 4700 Pressure Transmitter Ex application SIL2 Pld
Product brochure EN

(1.08 MB)

HDA 4400/4700-CC(SC) Safety manual D/E
Operating/maintenance instructions EN

(1.17 MB)