HDA 7400 – Relative pressure, accuracy 0.5%, industry, mobile, OEM

  • Stainless steel measuring sensor with thin-film strain gauge
  • Measuring range 6…1000 bar
  • Accuracy ± 0.5% FS type; ± 1.0% FS max
  • Analog/CAN
  • Options:
    • Flush membrane
SKU
GP_1000213557
Product Search
Filter selection
Reset filter
Pressure unit
Select all Reset selection
Setting range max value
Select all Reset selection
Output signal
Select all Reset selection
Mechanical connection
Select all Reset selection
Show more filters
Grouped product items
HDA 7446-A-400-000
Material-No. 907920
Setting range min value:
0
Setting range max value:
400
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7446-B-400-000
Material-No. 907930
Setting range min value:
0
Setting range max value:
400
Output signal:
0 to 10V
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7446-B-100-000
Material-No. 908105
Setting range min value:
0
Setting range max value:
100
Output signal:
0 to 10V
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7446-B-060-000
Material-No. 908114
Setting range min value:
0
Setting range max value:
60
Output signal:
0 to 10V
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7446-B-250-000
Material-No. 908115
Setting range min value:
0
Setting range max value:
250
Output signal:
0 to 10V
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7446-B-600-000
Material-No. 908116
Setting range min value:
0
Setting range max value:
600
Output signal:
0 to 10V
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7446-A-600-000
Material-No. 908250
Setting range min value:
0
Setting range max value:
600
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7446-A-250-000
Material-No. 908317
Setting range min value:
0
Setting range max value:
250
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7476-B-5000-000(psi)
Material-No. 908357
Setting range min value:
0
Setting range max value:
5000
Output signal:
0 to 10V
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7486-A-7500-000(psi)
Material-No. 908658
Setting range min value:
0
Setting range max value:
7500
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7446-A-060-000
Material-No. 908790
Setting range min value:
0
Setting range max value:
60
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7476-A-1000-000(psi)
Material-No. 920030
Setting range min value:
0
Setting range max value:
1000
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7476-A-3000-000(psi)
Material-No. 920076
Setting range min value:
0
Setting range max value:
3000
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7476-A-6000-000(psi)
Material-No. 920465
Setting range min value:
0
Setting range max value:
6000
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7476-A-0300-000(psi)
Material-No. 921021
Setting range min value:
0
Setting range max value:
300
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7448-F11-0400-000
Material-No. 921146
Setting range min value:
0
Setting range max value:
400
Output signal:
CANopen
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7448-F11-0100-000
Material-No. 921153
Setting range min value:
0
Setting range max value:
100
Output signal:
CANopen
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7446-B-040-000
Material-No. 921209
Setting range min value:
0
Setting range max value:
40
Output signal:
0 to 10V
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7476-B-3000-000(psi)
Material-No. 921218
Setting range min value:
0
Setting range max value:
3000
Output signal:
0 to 10V
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
HDA 7448-F11-0250-000
Material-No. 921285
Setting range min value:
0
Setting range max value:
250
Output signal:
CANopen
Approvals and certificates:
UL approval
PCE
Add to my list
Note: In the "My List" section, you can remember products and request them.
Page

Downloads

CAD data can’t be found at the product category level. Instead, it can be found directly at an individual product level.
Media
HDA 7446 Operating instructions D/E
Operating/maintenance instructions EN

(5.64 MB)

HDA 7400/7700 CANopen Protocol description E
Operating/maintenance instructions EN

(0.95 MB)

HDA 7400/7700 CANopen+SAE J1939 User manual D/E
Operating/maintenance instructions EN

(0.3 MB)

HDA 4700/7400/7700 SAE J1939 Protocol description D/E
Operating/maintenance instructions EN

(0.24 MB)

HDA 7400 Quick guide D/E
Operating/maintenance instructions EN

(1.01 MB)

HDA 7446 Pressure Transmitter
Product brochure EN

(0.89 MB)

HDA 7400 Pressure Transmitter for series applications
Product brochure EN

(0.87 MB)

HDA 7400 Pressure Transmitter CAN interface
Product brochure EN

(0.97 MB)

HDA 7400 Pressure Transmitter Flush membrane
Product brochure EN

(4.36 MB)